Manufacturer for Omega Load Cell - Single Point Load Cell-SPC – JIAJIA
Manufacturer for Omega Load Cell - Single Point Load Cell-SPC – JIAJIA Detail:
Detail Product Description
Emax[kg] |
1000、1500 |
2000、2500 |
M |
M10 |
M12 |
Application
Specifications: Exc+(Red); Exc-(Black); Sig+(Green);Sig-(White)
Item |
Unit |
Parameter |
Accuracy class |
|
0.03、0.05 |
Maximum capacity(Emax) |
kg |
250、300、500、800、1000 |
Sensitivity(Cn)/Zero balance |
mV/V |
2±0.2/0±0.1 |
Temperature effect on zero balance (TKo) |
% of Cn/10K |
±0.0175 |
Temperature effect on sensitivity(TKc) |
% of Cn/10K |
±0.0175 |
Hysteresis error(dhy) |
% of Cn |
±0.02 |
Non-linearity(dlin) |
% of Cn |
±0.0270 |
Creep(dcr) over 30 min |
% of Cn |
±0.0250 |
Eccentric error |
% |
±0.0233 |
Input (RLC) & Output resistance(R0) |
Ω |
400±20 & 352±3 |
Nominal range of excitation voltage(Bu) |
V |
5~15 |
Insulation resistance (Ris) at50Vdc |
MΩ |
>5000 |
Service temperature range(Btu) |
℃ |
-20…+50 |
Safe load limit(EL) & Breaking load(Ed) |
% of Emax |
150 & 200 |
Protection class according to EN 60 529 (IEC 529) |
|
IP67 |
Material:Measuring element |
|
Alloy steel、Stainless steel |
Maximum capacity(Emax)
Min.load cell verification inter(vmin) |
kg kg |
250 0.05 |
300 0.1 |
500 0.1 |
800 0.2 |
1000 0.2 |
Maximum platform size |
mm |
600 ×500 |
||||
Deflection at Emax(snom),approx |
mm |
<0.5 |
||||
Weight(G),approx |
kg |
1.8 |
||||
Cable:Diameter:Φ5mm length |
m |
3 |
||||
Mounting:Cylindrical head screw |
|
M10-10.9(1t~1.5t);M12-10.9(2t~2.5t) |
||||
Tightening torque |
N.m |
1t~1.5t:68N.m;2t~2.5t:100N.m |
Maximum capacity (Emax) |
t |
10 |
15 |
20 |
30 |
40 |
60 |
Deflection at Emax(snom),approx |
mm |
0.5 |
0.6 |
||||
Weight(G),approx |
kg |
17 |
26 |
||||
Cable:Diameter:Φ6mm length |
m |
8 |
10 |
12 |
16 |
16 |
Advantage
1. Years of R&D, production and sales experience, advanced and maturity technology.
2. High precision, durability, interchangeable with sensors produced by many famous brands, competitive price, and high-cost performance.
3. Excellent engineer team, customize different sensors and solutions for different needs.
Why choose us
YantaiJiaijia Instrument Co., Ltd. is an enterprise that emphasizes development and quality. With stable and reliable product quality and good business reputation, we have won the trust of our customers, and we have followed the market development trend and continuously developed new products to meet the needs of our customers. All products have passed internal quality standards.
Product detail pictures:

Related Product Guide:
Why is there an error in weight calibration?
New weights and their correct classification method
Assume full responsibility to satisfy all needs of our clients; achieve continual advancements by endorsing the expansion of our purchasers; turn into the final permanent cooperative partner of clientele and maximize the interests of clients for Manufacturer for Omega Load Cell - Single Point Load Cell-SPC – JIAJIA , The product will supply to all over the world, such as: Georgia, Puerto Rico, New Zealand, The president and all the company members would like to provide professional products and services for customers and sincerely welcome and cooperate with all native and foreign customers for a bright future.

High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.