Manufacturer for Omega Load Cell - Single Point Load Cell-SPD – JIAJIA
Manufacturer for Omega Load Cell - Single Point Load Cell-SPD – JIAJIA Detail:
Detail Product Description
Application
Specifications: Exc+(Red); Exc-(Black); Sig+(Green);Sig-(White)
Item |
Unit |
Parameter |
|
Accuracy class to OIML R60 |
|
C2 |
C3 |
Maximum capacity(Emax) |
kg |
10、15、20、30、40 |
|
Sensitivity(Cn)/Zero balance |
mV/V |
2.0±0.2/0±0.1 |
|
Temperature effect on zero balance (TKo) |
% of Cn/10K |
±0.02 |
±0.0170 |
Temperature effect on sensitivity(TKc) |
% of Cn/10K |
±0.02 |
±0.0170 |
Hysteresis error(dhy) |
% of Cn |
±0.02 |
±0.0180 |
Non-linearity(dlin) |
% of Cn |
±0.0270 |
±0.0167 |
Creep(dcr) over 30 min |
% of Cn |
±0.0250 |
±0.0167 |
Eccentric error |
% of Cn |
±0.0233 |
|
Input (RLC) & Output resistance(R0) |
Ω |
400±20 & 352±3 |
|
Nominal range of excitation voltage(Bu) |
V |
5~12 |
|
Insulation resistance (Ris) at50Vdc |
MΩ |
≥5000 |
|
Service temperature range(Btu) |
℃ |
-20…+50 |
|
Safe load limit(EL) & Breaking load(Ed) |
% of Emax |
120 & 200 |
|
Protection class according to EN 60 529 (IEC 529) |
|
IP65 |
|
Material:Measuring element |
|
Alloy steel |
Maximum capacity(Emax)
Min.load cell verification inter(vmin) |
kg g |
10 2 |
15 5 |
20 5 |
30 5 |
40 10 |
Deflection at Emax(snom),approx |
mm |
<0.5 |
||||
Weight(G),approx |
kg |
0.17 |
||||
Cable:Diameter:Φ5mm length |
m |
1.5 |
||||
Mounting:Cylindrical head screw |
|
M6-8.8 |
||||
Tightening torque |
N.m |
10N.m |
Advantage
1. Years of R&D, production and sales experience, advanced and maturity technology.
2. High precision, durability, interchangeable with sensors produced by many famous brands, competitive price, and high-cost performance.
3. Excellent engineer team, customize different sensors and solutions for different needs.
Why choose us
Different maximum capacities are available: 5 kg, 10 kg, 20 kg, 30 kg, 50 kg
Cable lengths range from 3 to 20 meters
Cable can be cut to length owing to the 6-wire configuration
Product detail pictures:

Related Product Guide:
New weights and their correct classification method
Why is there an error in weight calibration?
We now have our individual sales group, layout team, technical team, QC crew and package group. Now we have strict high-quality control procedures for each procedure. Also, all of our workers are experienced in printing discipline for Manufacturer for Omega Load Cell - Single Point Load Cell-SPD – JIAJIA , The product will supply to all over the world, such as: America, Brasilia, Guinea, To work with an excellent products manufacturer, our company is your best choice. Warmly welcome you and opening up the boundaries of communication. We are the ideal partner of your business development and look forward to your sincere cooperation.

The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly