Application
Specifications: Exc+(Red); Exc-(Black); Sig+(Green);Sig-(White)
Item |
Unit |
Parameter |
|
Accuracy class to OIML R60 |
|
C2 |
C3 |
Maximum capacity(Emax) |
kg |
10、15、20、30、40 |
|
Sensitivity(Cn)/Zero balance |
mV/V |
2.0±0.2/0±0.1 |
|
Temperature effect on zero balance (TKo) |
% of Cn/10K |
±0.02 |
±0.0170 |
Temperature effect on sensitivity(TKc) |
% of Cn/10K |
±0.02 |
±0.0170 |
Hysteresis error(dhy) |
% of Cn |
±0.02 |
±0.0180 |
Non-linearity(dlin) |
% of Cn |
±0.0270 |
±0.0167 |
Creep(dcr) over 30 min |
% of Cn |
±0.0250 |
±0.0167 |
Eccentric error |
% of Cn |
±0.0233 |
|
Input (RLC) & Output resistance(R0) |
Ω |
400±20 & 352±3 |
|
Nominal range of excitation voltage(Bu) |
V |
5~12 |
|
Insulation resistance (Ris) at50Vdc |
MΩ |
≥5000 |
|
Service temperature range(Btu) |
℃ |
-20…+50 |
|
Safe load limit(EL) & Breaking load(Ed) |
% of Emax |
120 & 200 |
|
Protection class according to EN 60 529 (IEC 529) |
|
IP65 |
|
Material:Measuring element |
|
Alloy steel |
Maximum capacity(Emax)
Min.load cell verification inter(vmin) |
kg g |
10 2 |
15 5 |
20 5 |
30 5 |
40 10 |
Deflection at Emax(snom),approx |
mm |
<0.5 |
||||
Weight(G),approx |
kg |
0.17 |
||||
Cable:Diameter:Φ5mm length |
m |
1.5 |
||||
Mounting:Cylindrical head screw |
|
M6-8.8 |
||||
Tightening torque |
N.m |
10N.m |
Advantage
1. Years of R&D, production and sales experience, advanced and maturity technology.
2. High precision, durability, interchangeable with sensors produced by many famous brands, competitive price, and high-cost performance.
3. Excellent engineer team, customize different sensors and solutions for different needs.
Why choose us
Different maximum capacities are available: 5 kg, 10 kg, 20 kg, 30 kg, 50 kg
Cable lengths range from 3 to 20 meters
Cable can be cut to length owing to the 6-wire configuration
Product detail pictures:

Related Product Guide:
Why is there an error in weight calibration?
New weights and their correct classification method
owing to good service, a variety of high quality products, competitive prices and efficient delivery, we enjoy a good reputation among our customers. We are an energetic company with wide market for Manufacturer for Omega Load Cell - Single Point Load Cell-SPD – JIAJIA , The product will supply to all over the world, such as: Jeddah, Honduras, Moldova, Each customer's satisfactory is our goal. We are looking for long-term cooperation with each customer. To meet this, we keep up our quality and provide extraordinary customer service. Welcome to our company, we are expecting to cooperate with you.

The supplier abide the theory of "quality the basic, trust the first and management the advanced" so that they can ensure a reliable product quality and stable customers.