Specifications
|
Weighing pan |
30*30cm |
30*40cm |
40*50cm |
45*60cm |
50*60cm |
60*80cm |
|
Capacity |
30kg |
60kg |
150kg |
200kg |
300kg |
500kg |
|
Accuracy |
2g |
5g |
10g |
20g |
50g |
100g |
|
Support customization of various sizes of countertops |
||||||
| Model | NVK-A27E |
| Index value | 1/2/5/10/20/50 optional |
| Maximum verification division | 3000 |
| Input signal range | -19mv~19mv |
| Conversion speed | 10 times/sec |
| Nonlinear | 0.0015% |
| Gain drift | 0.03% |
| Load cell connection | 1 350Ω Load cell |
| Display range | -99999~99999((do not consider the decimal point) |
| Baud rate | 1200/2400/4800/9600 |
| Signal | RS232 signal |
| Transmission distance | <20 meters |
| Supply bridge voltage | DC 5V |
| Power supply | AC220V; 50,60Hz(-2%~+2%) |
| Operating temperature | 0℃~40℃ |
| Storage temperature | -25℃~55℃ |
| Relative humidity | ≤85%RH |
| Communication interface | RS 232 serial,20mA current loop(constant current source)signal large screen interface |
| Size | A:236mm B:161mm C:168mm D:800mm |
Features
1.Single window 2 inch special highlight LED display
2.Peak hold and average display during weighing, automatic sleep without weighing
3.Preset tare weight, manual accumulation and automatic accumulation
4.Four-level batteru indicator, undervoltage alarm and automatic shutdown function
5.Upper and lower limit alarm function, HIGH-OK-LOW status indication
6.Accuracy 10 times automatic magnification function
7.High-precision digital-to-analog conversion technology with readability of 1/30000
8.Random configuration 6V/4AH maintenance-free battery, can be randomly charged
9.Optional RS-232C communication port, optional baud rate
10.Optional large screen communication port, 20mA current loop connection mode technical parameters
Product detail pictures:
Related Product Guide:
New weights and their correct classification method
Why is there an error in weight calibration?
As for competitive selling prices, we believe that you will be searching far and wide for anything that can beat us. We will state with absolute certainty that for such excellent at such charges we are the lowest around for New Fashion Design for Ir Moisture Analyzer – aA27 platform scale – JIAJIA , The product will supply to all over the world, such as: Swaziland, Irish, Colombia, We have advanced production technology, and pursuit innovative in goods. At the same time, the good service has enhanced the good reputation. We believe that as long as you understand our product, you need to be willing to become partners with us. Looking forward to your inquiry.
The factory technical staff gave us a lot of good advice in the cooperation process, this is very good, we are very grateful.