One of Hottest for Siemens Load Cell - Column Type-CTB/CTBY – JIAJIA
One of Hottest for Siemens Load Cell - Column Type-CTB/CTBY – JIAJIA Detail:
Application
Specifications: Exc+(Red); Exc-(Black); Sig+(Green);Sig-(White)
Item |
Unit |
Parameter |
|
Accuracy class to OIML R60 |
|
C2 |
C3 |
Maximum capacity(Emax) |
t |
5、10、20、30 |
|
Minimum LC verification interval(Vmin) |
% of Emax |
0.0200 |
0.0100 |
Sensitivity(Cn)/Zero balance |
mV/V |
2.0±0.002/0±0.02 |
|
Temperature effect on zero balance (TKo) |
% of Cn/10K |
±0.02 |
±0.0170 |
Temperature effect on sensitivity(TKc) |
% of Cn/10K |
±0.02 |
±0.0170 |
Hysteresis error(dhy) |
% of Cn |
±0.0270 |
±0.0180 |
Non-linearity(dlin) |
% of Cn |
±0.0250 |
±0.0167 |
Creep(dcr) over 30 min |
% of Cn |
±0.030 |
±0.0167 |
Input (RLC) & Output resistance(R0) |
Ω |
CTB:400±10 & 352±3 CTBY:700±20 & 706±7 |
|
Nominal range of excitation voltage(Bu) |
V |
5~15 |
|
Insulation resistance (Ris) at50Vdc |
MΩ |
≥5000 |
|
Service temperature range(Btu) |
℃ |
-30…+70 |
|
Safe load limit(EL) & Breaking load(Ed) |
% of Emax |
150 & 250 |
|
Protection class according to EN 60 529 (IEC 529) |
|
IP68 |
|
Material:Measuring element+housing |
|
Stainless or alloy steel+Stainless steel |
Maximum capacity (Emax) |
t |
5 |
10 |
20 |
30 |
Min.scale verification(emin)
according to En45501 [...#=max.Number of load cells] |
kg |
2 [4#] |
5 [6#] |
5 [6#] |
10 [10#] |
Deflection at Emax(snom),approx |
mm |
0.55 |
0.55 |
0.65 |
0.75 |
Weight(G),approx |
kg |
1.8 |
1.9 |
2.1 |
2.3 |
Cable:Diameter:Φ6mm length |
m |
8 |
10 |
12 |
15 |
Advantage
1. Years of R&D, production and sales experience, advanced and maturity technology.
2. High precision, durability, interchangeable with sensors produced by many famous brands, competitive price, and high-cost performance.
3. Excellent engineer team, customize different sensors and solutions for different needs.
Why choose us
YantaiJiaijia Instrument Co., Ltd. is an enterprise that emphasizes development and quality. With stable and reliable product quality and good business reputation, we have won the trust of our customers, and we have followed the market development trend and continuously developed new products to meet the needs of our customers. All products have passed internal quality standards.
Product detail pictures:

Related Product Guide:
Why is there an error in weight calibration?
New weights and their correct classification method
Our growth depends to the superior products ,great talents and repeatedly strengthened technology forces for One of Hottest for Siemens Load Cell - Column Type-CTB/CTBY – JIAJIA , The product will supply to all over the world, such as: Haiti, Mauritius, Tunisia, With strong technical strength and advanced production equipment, and SMS people purposefully , professional, dedicated spirit of enterprise. Enterprises took the lead through the ISO 9001:2008 international quality management system certification, CE certification EU ; CCC.SGS.CQC other related product certification. We look forward to reactivating our company connection.

This is a very professional wholesaler, we always come to their company for procurement, good quality and cheap.