One of Hottest for Siemens Load Cell - Single Point Load Cell-SPL – JIAJIA
One of Hottest for Siemens Load Cell - Single Point Load Cell-SPL – JIAJIA Detail:
Application
Specifications: Exc+(Red); Exc-(Black); Sig+(Green);Sig-(White)
Item |
Unit |
Parameter |
Accuracy class to OIML R60 |
|
D1 |
Maximum capacity(Emax) |
kg |
500,800 |
Sensitivity(Cn)/Zero balance |
mV/V |
2.0±0.2/0±0.1 |
Temperature effect on zero balance (TKo) |
% of Cn/10K |
±0.0175 |
Temperature effect on sensitivity(TKc) |
% of Cn/10K |
±0.0175 |
Hysteresis error(dhy) |
% of Cn |
±0.0500 |
Non-linearity(dlin) |
% of Cn |
±0.0500 |
Creep(dcr) over 30 min |
% of Cn |
±0.0250 |
Input (RLC) & Output resistance(R0) |
Ω |
1100±10 & 1002±3 |
Nominal range of excitation voltage(Bu) |
V |
5~15 |
Insulation resistance (Ris) at50Vdc |
MΩ |
≥5000 |
Service temperature range(Btu) |
℃ |
-20…+50 |
Safe load limit(EL) & Breaking load(Ed) |
% of Emax |
120 & 200 |
Protection class according to EN 60 529 (IEC 529) |
|
IP65 |
Material:Measuring element |
|
Alloy steel |
Maximum capacity(Emax)
Min.load cell verification inter(vmin) |
kg g |
500 100 |
800 200 |
Deflection at Emax(snom),approx |
mm |
<0.6 |
|
Weight(G),approx |
kg |
1 |
|
Cable(flat cable) length |
m |
0.5 |
|
Mounting:Cylindrical head screw |
|
M12-10.9 |
|
Tightening torque |
N.m |
42N.m |
Features
-
Low Profile/Compact Size
0.03% Accuracy Class
Aluminum Alloy
IP66/67 Environmental Sealing
Good Price/Performance Ratio
One Year Warranty
When to use a loadcell
Load cell measures mechanical force, mainly the weight of objects. Today, almost all electronic weighing scales use load cells for the measurement of weight. They are widely used because of the accuracy with which they can measure the weight. Load cells find their application in a variety of fields that demand accuracy and precision. There are different classes to load cells, class A, class B, class C & Class D, and with each class, there is a change in both accuracy and capacity.
Product detail pictures:


Related Product Guide:
New weights and their correct classification method
Why is there an error in weight calibration?
Our business puts emphasis over the administration, the introduction of talented staff, plus the construction of team building, attempting hard to boost the standard and liability consciousness of personnel customers. Our corporation successfully attained IS9001 Certification and European CE Certification of One of Hottest for Siemens Load Cell - Single Point Load Cell-SPL – JIAJIA , The product will supply to all over the world, such as: Argentina, Czech republic, Tanzania, We warmly welcome you to come to visit us personally. We hope to establish a long-term friendship based on equality and mutual benefit. If you want to get in touch with us, please do not hesitate to call. We will be your best choice.

Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.