Specifications: Exc+(Red); Exc-(Black); Sig+(Green);Sig-(White)
Item |
Unit |
Parameter |
|
Accuracy class to OIML R60 |
|
C2 |
C3 |
Maximum capacity(Emax) |
t |
0.5、1、2 |
|
Minimum LC verification interval(Vmin) |
% of Emax |
0.0200 |
|
Sensitivity(Cn)/Zero balance |
mV/V |
2.0±0.002/0±0.02 |
|
Temperature effect on zero balance (TKo) |
% of Cn/10K |
±0.02 |
±0.0170 |
Temperature effect on sensitivity(TKc) |
% of Cn/10K |
±0.02 |
±0.0170 |
Hysteresis error(dhy) |
% of Cn |
±0.0330 |
±0.0180 |
Non-linearity(dlin) |
% of Cn |
±0.0250 |
±0.0167 |
Creep(dcr) over 30 min |
% of Cn |
±0.0233 |
±0.0167 |
Input (RLC) & Output resistance(R0) |
Ω |
400±10 & 352±3 |
|
Nominal range of excitation voltage(Bu) |
V |
5~15 |
|
Insulation resistance (Ris) at50Vdc |
MΩ |
>5000 |
|
Service temperature range(Btu) |
℃ |
-30…+70 |
|
Safe load limit(EL) & Breaking load(Ed) |
% of Emax |
150 & 200 |
|
Protection class according to EN 60 529 (IEC 529) |
|
IP68 |
|
Material:Measuring element
Cable fitting Cable sheath |
|
Stainless or volly steel Stainless steel or nickel-plated brass PVC |
Maximum capacity (Emax) |
t |
0.5 |
1 |
2 |
Deflection at Emax(snom),approx |
mm |
<0.5 |
<0.5 |
<0.6 |
Weight(G),approx |
kg |
1.3 |
||
Cable:Diameter:Φ6mm length |
m |
3.5 |
Advantage
1. Years of R&D, production and sales experience, advanced and maturity technology.
2. High precision, durability, interchangeable with sensors produced by many famous brands, competitive price, and high-cost performance.
3. Excellent engineer team, customize different sensors and solutions for different needs.
Why choose us
YantaiJiaijia Instrument Co., Ltd. is an enterprise that emphasizes development and quality. With stable and reliable product quality and good business reputation, we have won the trust of our customers, and we have followed the market development trend and continuously developed new products to meet the needs of our customers. All products have passed internal quality standards.
Product detail pictures:

Related Product Guide:
New weights and their correct classification method
Why is there an error in weight calibration?
We take pleasure in an exceptionally excellent status between our buyers for our superb merchandise good quality, aggressive price tag and the greatest support for PriceList for Mettler Toledo Load Cell - Shear Beam-SBB – JIAJIA , The product will supply to all over the world, such as: Grenada, Liverpool, Philadelphia, We have top engineers in these industries and an efficient team in the research. What is more, now we have our own archives mouths and markets in China at low cost. Therefore, we can meet different inquiries from different clients. Remember to find our website to check more information from our merchandise.

Problems can be quickly and effectively resolved, it is worth to be trust and working together.