Innovation, excellent and reliability are the core values of our company. These principles today much more than ever form the basis of our success as an internationally active mid-size business for Cattle Scales Platform , Portable Industrial Scales , Analytical Balance Calibration Weights , As an expert specialized within this field, we've been committed to solving any problem of high temperature protection for users.
PriceList for Mettler Toledo Load Cell - Single Point Load Cell-SPL – JIAJIA Detail:

Application

Specifications:  Exc+(Red); Exc-(Black); Sig+(Green);Sig-(White) 

Item

Unit

Parameter

Accuracy class to OIML R60

D1

Maximum capacity(Emax)

kg

500,800

Sensitivity(Cn)/Zero balance

mV/V

2.0±0.2/0±0.1

Temperature effect on zero balance (TKo)

% of Cn/10K

±0.0175

Temperature effect on sensitivity(TKc)

% of Cn/10K

±0.0175

Hysteresis error(dhy)

% of Cn

±0.0500

Non-linearity(dlin)

% of Cn

±0.0500

Creep(dcr) over 30 min

% of Cn

±0.0250

Input (RLC) & Output resistance(R0)

Ω

1100±10 & 1002±3

Nominal range of excitation voltage(Bu)

V

5~15

Insulation resistance (Ris) at50Vdc

≥5000

Service temperature range(Btu)

-20…+50

Safe load limit(EL) & Breaking load(Ed)

% of Emax

120 & 200

Protection class according to EN 60 529 (IEC 529)

IP65

Material:Measuring element

Alloy steel

Maximum capacity(Emax)

Min.load cell verification inter(vmin)

kg

g

500

100

800

200

Deflection at Emax(snom),approx

mm

<0.6

Weight(G),approx

kg

1

Cable(flat cable) length

m

0.5

Mounting:Cylindrical head screw

M12-10.9

Tightening torque

N.m

42N.m

Features

  • Low Profile/Compact Size

    0.03% Accuracy Class

    Aluminum Alloy

    IP66/67 Environmental Sealing

    Good Price/Performance Ratio

    One Year Warranty

When to use a loadcell

Load cell measures mechanical force, mainly the weight of objects. Today, almost all electronic weighing scales use load cells for the measurement of weight. They are widely used because of the accuracy with which they can measure the weight. Load cells find their application in a variety of fields that demand accuracy and precision. There are different classes to load cells, class A, class B, class C & Class D, and with each class, there is a change in both accuracy and capacity.


Product detail pictures:

PriceList for Mettler Toledo Load Cell - Single Point Load Cell-SPL – JIAJIA detail pictures

PriceList for Mettler Toledo Load Cell - Single Point Load Cell-SPL – JIAJIA detail pictures


Related Product Guide:
New weights and their correct classification method
Why is there an error in weight calibration?

We have now a skilled, performance group to offer excellent support for our consumer. We usually follow the tenet of customer-oriented, details-focused for PriceList for Mettler Toledo Load Cell - Single Point Load Cell-SPL – JIAJIA , The product will supply to all over the world, such as: Uruguay, Spain, Slovakia, With the principle of win-win, we hope to help you make more profits in the market. An opportunity is not to be caught, but to be created. Any trading companies or distributors from any countries are welcomed.
  • The customer service reprersentative explained very detailed, service attitude is very good, reply is very timely and comprehensive, a happy communication! We hope to have a opportunity to cooperate.
    5 Stars By Dorothy from Leicester - 2018.02.21 12:14
    We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
    5 Stars By Helen from Johannesburg - 2017.05.02 11:33
    Write your message here and send it to us